Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	32
Date	08/07/14
Start Time	16:02:32
Diameter Midpoint
 11.3	838968
 11.8	882729
 12.2	828661
 12.6	841891
 13.1	844121
 13.6	851331
 14.1	846107
 14.6	851041
 15.1	848522
 15.7	842322
 16.3	821795
 16.8	803791
 17.5	769546
 18.1	731833
 18.8	690288
 19.5	648394
 20.2	597291
 20.9	540567
 21.7	487650
 22.5	432704
 23.3	371819
 24.1	316358
 25.0	265828
 25.9	220496
 26.9	181299
 27.9	144177
 28.9	115011
 30.0	88293.5
 31.1	72406
 32.2	59036.9
 33.4	51319.9
 34.6	46564.6
 35.9	44382.2
 37.2	44392.1
 38.5	43669.3
 40.0	44476.2
 41.4	44101
 42.9	43794.1
 44.5	41071.2
 46.1	37296.4
 47.8	31519.3
 49.6	26146
 51.4	20094.4
 53.3	15472.4
 55.2	12699.4
 57.3	9571.68
 59.4	8062.51
 61.5	6522.57
 63.8	5077.3
 66.1	4224.05
 68.5	3330.69
 71.0	2676.03
 73.7	1915.12
 76.4	1614.31
 79.1	1251.9
 82.0	939.734
 85.1	741.5
 88.2	735.939
 91.4	578.941
 94.7	491.972
 98.2	360.061
101.8	317.925
105.5	253.12
109.4	264.19
113.4	239.492
117.6	155.216
121.9	171.43
126.3	131.483
131.0	103.895
135.8	87.6772
140.7	63.3885
145.9	70.6016
151.2	63.3962
156.8	66.8134
162.5	44.6524
168.5	28.5947
174.7	38.726
181.1	28.2117
187.7	28.8497
194.6	42.2867
201.7	20.8704
209.1	34.5477
216.7	43.1269
224.7	30.819
232.9	28.6843
241.4	28.7679
250.3	30.2554
259.5	18.0637
269.0	17.9816
278.8	16.8408
289.0	16.9485
299.6	19.3959
310.6	18.5163
322.0	16.0526
333.8	12.129
346.0	8.17876
358.7	14.1748
371.8	21.9845
385.4	9.88291
399.5	8.15887
414.2	9.94322
429.4	7.64141
445.1	11.4871
461.4	1.21509
478.3	3.71223
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.6836
High Voltage	9932.45
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	16.137
Mean(nm)	17.8005
Geo. Mean(nm)	16.8978
Mode(nm)	11.7574
Geo. Std. Dev.	1.35264
Total Concentration(#/cm)	1.7432e+007
Comment	